Mechanical Systems & Equipment Maintenance

Hands-on mechanical maintenance — piping, chillers, and vibration diagnostics.

4 hrs · self-paced online Cooling & Efficiency

Mechanical operations for technicians: HVAC systems, piping, chiller operation, water treatment, and vibration analysis. Lab sessions include hands-on diagnostics, so the techniques transfer directly to your equipment.

You'll leave with equipment maintenance protocols built around predictive maintenance and vendor coordination, reducing unplanned mechanical downtime.

What You'll Learn

  • Maintain piping systems and water treatment programs correctly
  • Operate and maintain chillers to manufacturer and best-practice standards
  • Use vibration analysis to catch mechanical problems before failure
  • Build equipment maintenance protocols with vendor coordination built in

Course Modules

Piping Systems & Water Treatment

Water treatment practices that extend piping and equipment life.

Chiller Operation & Maintenance

Operating and maintaining chillers for reliability and efficiency.

Vibration Analysis & Equipment Health

Reading vibration data to catch mechanical failures early.

Lifecycle Planning & Vendor Coordination

Coordinating vendor service around equipment lifecycle planning.

Why This Matters in a Data Center

Chillers, pumps, cooling towers and piping keep a data center's heat moving out of the building. They run continuously, often for years without a full shutdown, so maintenance has to be planned carefully and done without losing cooling redundancy.

Water quality and equipment condition cause many mechanical failures. Poor water treatment leads to scale, corrosion and biological growth, including Legionella risk in cooling towers, which ASHRAE Standard 188 addresses. Vibration analysis can find bearing wear, misalignment and imbalance in pumps and fans long before they fail. This course covers piping and water treatment, chiller operation and maintenance, vibration analysis and lifecycle planning with vendors.

Who This Course Is For

Audience: Mechanical technicians responsible for facility equipment maintenance.

Course Details

Frequently Asked Questions

Why is water treatment important for data center cooling?

Untreated water causes scale that reduces heat transfer, corrosion that damages pipes and equipment, and biological growth that fouls systems and can create health risks. A water treatment program keeps chillers and towers efficient and reliable.

What can vibration analysis detect?

Vibration analysis can detect imbalance, misalignment, looseness, bearing wear and some electrical faults in rotating equipment such as pumps, fans and compressors, often months before failure.

How do you maintain a chiller without losing cooling?

By planning around redundancy: confirming the remaining chillers can carry the load, following a method of procedure, scheduling during cooler conditions or lower load when possible, and having a backout plan. The course covers this within chiller operations and lifecycle planning.

Related Courses

More training from the Cooling & Facilities Efficiency Bundle. Browse all 43 courses or save with a bundle.

Cooling Systems Design & Optimization

Cooling & Efficiency·Comprehensive Program
8 hrs
$298.99

HVAC Systems Troubleshooting Essentials

Cooling & Efficiency·Modular Specialization
4 hrs
$99.99

Energy Efficiency & PUE Optimization

Cooling & Efficiency·Modular Specialization
4 hrs
$99.99

Data Center Cooling System and Refrigerant Safety Training

Cooling & Efficiency·Modular Specialization
2 hrs
$99.99

Building Envelope Fundamentals

Cooling & Efficiency·Modular Specialization
2 hrs
$99.99

Ready to Enroll Your Team?

Enroll online and pay by card, and learner logins arrive by email. For a bundle or purchase-order billing, send an enrollment request, or call or email us.